{"id":5825,"date":"2021-07-30T12:17:21","date_gmt":"2021-07-30T15:17:21","guid":{"rendered":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/?p=5825"},"modified":"2021-08-02T10:00:28","modified_gmt":"2021-08-02T13:00:28","slug":"5825-2","status":"publish","type":"post","link":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/5825-2\/","title":{"rendered":"UTILIZA\u00c7\u00c3O DE GEOT\u00caXTIL BIDIM EM MURO MISTO DE SOLO REFOR\u00c7ADO E SOLO GRAMPEADO NA BASE S\u00c3O JOS\u00c9 DOS CAMPOS SP"},"content":{"rendered":"\n<p><strong><span style=\"color:#434343\" class=\"has-inline-color\">Autor:<\/span><\/strong> Departamento T\u00e9cnico &#8211; Atividade Bidim<\/p>\n\n\n\n<h3><span style=\"color:#434343\" class=\"has-inline-color\">DADOS GERAIS<\/span><\/h3>\n\n\n\n<p>Assunto<\/p>\n\n\n\n<p>Utiliza\u00e7\u00e3o de geot\u00eaxtil Bidim em muro misto de solo refor\u00e7ado e solo grampeado na base.<\/p>\n\n\n\n<p>Local<\/p>\n\n\n\n<p>&nbsp;&nbsp; , SP<\/p>\n\n\n\n<h4>Descri\u00e7\u00e3o do problema<\/h4>\n\n\n\n<p>Necessidade de execu\u00e7\u00e3o de muro de conten\u00e7\u00e3o em conjunto habitacional, com a peculiaridade do trecho inferior do maci\u00e7o apresentar pequena largura para o necess\u00e1rio comprimento de ancoragem do geot\u00eaxtil.<\/p>\n\n\n\n<h4>Descri\u00e7\u00e3o da solu\u00e7\u00e3o<\/h4>\n\n\n\n<p>Execu\u00e7\u00e3o de grampeamento pr\u00e9vio na base do maci\u00e7o, no local onde n\u00e3o h\u00e1 largura suficiente para o geot\u00eaxtil, e posterior conex\u00e3o entre os dois refor\u00e7os. No trecho superior, o muro foi executado de maneira convencional.<\/p>\n\n\n\n<h4>Vantagens da solu\u00e7\u00e3o<\/h4>\n\n\n\n<p>Custo reduzido em rela\u00e7\u00e3o a outras solu\u00e7\u00f5es como, por exemplo, muros de concreto armado; rapidez de execu\u00e7\u00e3o; f\u00e1cil transporte de material (Bidim).<\/p>\n\n\n\n<p>Quantidade<\/p>\n\n\n\n<p>Manta geot\u00eaxtil Bidim RT-31: 3.500 m\u00b2.<\/p>\n\n\n\n<p>Data de conclus\u00e3o<\/p>\n\n\n\n<p>Maio de 2005<\/p>\n\n\n\n<p>Propriet\u00e1rio<\/p>\n\n\n\n<p>Condom\u00ednio Residencial SJC<\/p>\n\n\n\n<h3><span style=\"color:#434343\" class=\"has-inline-color\">DESCRI\u00c7\u00c3O DO GEOSSINT\u00c9TICO UTILIZADO<\/span><\/h3>\n\n\n\n<h4>Manta Geot\u00eaxtil Bidim RT-31<\/h4>\n\n\n\n<p>MANTA GEOT\u00caXTIL N\u00c3OTECIDO 100% POLI\u00c9STER COM RESIST\u00caNCIA TRA\u00c7\u00c3O LONGITUDINAL M\u00cdNIMA DE 31 KN\/M E TRA\u00c7\u00c3O TRANSVERSAL M\u00cdNIMA DE 27 KN\/M<\/p>\n\n\n\n<h2><span style=\"color:#434343\" class=\"has-inline-color\">DESENHO ESQUEM\u00c1TICO<\/span><\/h2>\n\n\n\n<p>Figura 1 &#8211; Muro misto em solo envelopado e solo grampeado.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" width=\"464\" height=\"329\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image.png\" alt=\"\" class=\"wp-image-5829\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image.png 464w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-300x213.png 300w\" sizes=\"(max-width: 464px) 100vw, 464px\" \/><\/figure>\n\n\n\n<p>Notas construtivas: <em>(espec\u00edficas para o muro em an\u00e1lise)<\/em><\/p>\n\n\n\n<ol type=\"1\"><li>A superf\u00edcie natural \u00e9 escavada em degraus para evitar superf\u00edcie potencial de ruptura.<\/li><\/ol>\n\n\n\n<ul><li>O solo de aterro deve ser livre de mat\u00e9ria org\u00e2nica e blocos de grandes dimens\u00f5es. O solo deve ser compactado com sapo mec\u00e2nico em camadas com espessuras acabadas n\u00e3o superiores a 20 cm.<\/li><\/ul>\n\n\n\n<ul><li>No trecho inferior \u00e9 executada uma conten\u00e7\u00e3o com chumbadores conecta \u00e0s camadas de geot\u00eaxtil Bidim RT-31 devido ao pequeno espa\u00e7o dispon\u00edvel para refor\u00e7o. Os chumbadores s\u00e3o constitu\u00ed por furos preenchi com nata de cimento e barra de a\u00e7o com di\u00e2metro de 1\u201d.<\/li><\/ul>\n\n\n\n<ul><li>A face acabada \u00e9 protegida com parede de alvenaria para evitar a\u00e7\u00f5es de vandalismo e proteger o geot\u00eaxtil da a\u00e7\u00e3o direta raio ultravioleta. A parede deve ser engastada na superf\u00edcie do terreno de modo a prover a sua devida estabilidade. O espa\u00e7o vazio entre a face do maci\u00e7o e a parede \u00e9 preenchida com brita.<\/li><\/ul>\n\n\n\n<ul><li>Devem ser instala barbac\u00e3s na face de alvenaria.<\/li><\/ul>\n\n\n\n<h3 class=\"has-text-align-center\"><span style=\"color:#434343\" class=\"has-inline-color\">DOCUMENTA\u00c7\u00c3O FOTOGR\u00c1FICA<\/span><\/h3>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"403\" height=\"302\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-1.png\" alt=\"\" class=\"wp-image-5830\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-1.png 403w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-1-300x225.png 300w\" sizes=\"(max-width: 403px) 100vw, 403px\" \/><figcaption>Tubos para drenagem,<br>a ser executada no p\u00e9 do talude.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"404\" height=\"303\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-2.png\" alt=\"\" class=\"wp-image-5832\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-2.png 404w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-2-300x225.png 300w\" sizes=\"(max-width: 404px) 100vw, 404px\" \/><figcaption>Vista geral do talude de escava\u00e7\u00e3o.<br>Notar o talude escavado em degraus para evitar superf\u00edcie potencial de ruptura.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"227\" height=\"302\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-4.png\" alt=\"\" class=\"wp-image-5834\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-4.png 227w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-4-225x300.png 225w\" sizes=\"(max-width: 227px) 100vw, 227px\" \/><figcaption>Detalhe da trincheira drenante na regi\u00e3o anterior da face do muro.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"278\" height=\"302\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-6.png\" alt=\"\" class=\"wp-image-5836\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-6.png 278w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-6-276x300.png 276w\" sizes=\"(max-width: 278px) 100vw, 278px\" \/><figcaption>Detalhe do tubo dreno no p\u00e9 do muro.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"227\" height=\"302\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-8.png\" alt=\"\" class=\"wp-image-5839\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-8.png 227w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-8-225x300.png 225w\" sizes=\"(max-width: 227px) 100vw, 227px\" \/><figcaption>Detalhe da parede de prote\u00e7\u00e3o constitu\u00edda por blocos de concreto e armadura vertical. Notar tamb\u00e9m o espa\u00e7o entre o muro e o geot\u00eaxtil Bidim RT-31 preenchido com brita para drenagem.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"227\" height=\"303\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-10.png\" alt=\"\" class=\"wp-image-5841\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-10.png 227w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-10-225x300.png 225w\" sizes=\"(max-width: 227px) 100vw, 227px\" \/><figcaption>Vista geral da regi\u00e3o interna do muro em execu\u00e7\u00e3o.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"403\" height=\"301\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-12.png\" alt=\"\" class=\"wp-image-5843\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-12.png 403w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-12-300x224.png 300w\" sizes=\"(max-width: 403px) 100vw, 403px\" \/><figcaption>Detalhe da camada de geot\u00eaxtil Bidim RT-31 sendo dobrada no interior do muro.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"226\" height=\"301\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-13.png\" alt=\"\" class=\"wp-image-5844\"\/><figcaption>Detalhe da face do muro, notando-se os barbac\u00e3s para drenagem.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"403\" height=\"302\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-14.png\" alt=\"\" class=\"wp-image-5845\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-14.png 403w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/08\/image-14-300x225.png 300w\" sizes=\"(max-width: 403px) 100vw, 403px\" \/><figcaption>Vista geral do muro conclu\u00eddo.<\/figcaption><\/figure><\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Autor: Departamento T\u00e9cnico &#8211; Atividade Bidim DADOS GERAIS Assunto Utiliza\u00e7\u00e3o de geot\u00eaxtil Bidim em muro misto de solo refor\u00e7ado e solo grampeado na base. Local &nbsp;&nbsp; , SP Descri\u00e7\u00e3o do problema Necessidade de execu\u00e7\u00e3o de muro de conten\u00e7\u00e3o em conjunto habitacional, com a peculiaridade do trecho inferior do maci\u00e7o apresentar pequena largura para o necess\u00e1rio [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[54],"tags":[39],"_links":{"self":[{"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/posts\/5825"}],"collection":[{"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/comments?post=5825"}],"version-history":[{"count":7,"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/posts\/5825\/revisions"}],"predecessor-version":[{"id":5847,"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/posts\/5825\/revisions\/5847"}],"wp:attachment":[{"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/media?parent=5825"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/categories?post=5825"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/tags?post=5825"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}