{"id":2324,"date":"2021-06-21T12:33:41","date_gmt":"2021-06-21T15:33:41","guid":{"rendered":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/?p=2324"},"modified":"2021-06-22T09:34:38","modified_gmt":"2021-06-22T12:34:38","slug":"aplicacao-do-geotextil-bidim-como-camada-de-separacao-no-sistema-de-impermeabilizacao-do-edificio-jk-belo-horizonte-mg","status":"publish","type":"post","link":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/aplicacao-do-geotextil-bidim-como-camada-de-separacao-no-sistema-de-impermeabilizacao-do-edificio-jk-belo-horizonte-mg\/","title":{"rendered":"APLICA\u00c7\u00c3O DO GEOT\u00caXTIL BIDIM COMO CAMADA DE SEPARA\u00c7\u00c3O NO SISTEMA DE IMPERMEABILIZA\u00c7\u00c3O DO EDIF\u00cdCIO JK BELO HORIZONTE MG"},"content":{"rendered":"\n<p id=\"block-e8218be0-05cf-4d15-a4ca-81082185ab0c\" style=\"font-size:12px\"><strong><br>Autor:<\/strong>&nbsp;Departamento T\u00e9cnico \u2013 Atividade Bidim<\/p>\n\n\n\n<p id=\"block-0617ebb4-d288-4d42-90f1-5a40b97e58a6\" style=\"font-size:12px\">Revisado JANEIRO 2011- Departamento T\u00e9cnico Mexichem Bidim Ltda.\ufeff<\/p>\n\n\n\n<p id=\"block-0c31328f-d602-441f-9b7a-023e88a2c8d1\"><strong><span style=\"color:#434343\" class=\"has-inline-color\">RESUMO<\/span><\/strong><\/p>\n\n\n\n<p>O Edif\u00edcio Juscelino Kubistchek, mais conhecido como JK, \u00e9 um projeto do Arquiteto Oscar Niemayer constituindo-se num marco da Constru\u00e7\u00e3o Civil em Belo Horizonte. A aplica\u00e7\u00e3o do  geot\u00eaxtil Bidim \u00e9 vista como camada de prote\u00e7\u00e3o no sistema de impermeabiliza\u00e7\u00e3o do Edif\u00edcio Juscelino Kubitschek JK em Belo Horizonte, MG, que com o passar do tempo trouxe consigo os diversos problemas para o edif\u00edcio e dentre eles o de infiltra\u00e7\u00f5es.<\/p>\n\n\n\n<p id=\"block-c402eab3-3648-4b06-b856-9a930bb231eb\"><strong><span style=\"color:#434343\" class=\"has-inline-color\">O PROBLEMA<\/span><\/strong><\/p>\n\n\n\n<p id=\"block-c6cd034d-6e55-4e81-aad6-fb2e18839f09\">Implementar um sistema eficiente de impermeabiliza\u00e7\u00e3o do Edif\u00edcio Juscelino Kubitschek JK em Belo Horizonte, MG<\/p>\n\n\n\n<p id=\"block-64d055e1-f662-4a10-a39c-a0b9897fb900\"><strong><span style=\"color:#434343\" class=\"has-inline-color\">A SOLU\u00c7\u00c3O<\/span><\/strong><\/p>\n\n\n\n<p id=\"block-dbee7bcc-8a88-4479-af92-2b90d83ec0ea\">Foi utilizada a manda geot\u00eaxtil Bidim RT-10<\/p>\n\n\n\n<p id=\"block-1e24a5b8-4df1-4002-9f2a-53e1dcefc596\"><strong><span style=\"color:#434343\" class=\"has-inline-color\">DADOS DA OBRA<\/span><\/strong><\/p>\n\n\n\n<ul id=\"block-4b600ac6-56e0-4e23-95b0-f711a80defbe\" class=\"has-normal-font-size\"><li><span style=\"color:#434343\" class=\"has-inline-color\"><strong>DAT<\/strong><\/span><strong><span style=\"color:#434343\" class=\"has-inline-color\">A DE EXECU\u00c7\u00c3<\/span><\/strong><span style=\"color:#434343\" class=\"has-inline-color\"><strong>O:<\/strong><\/span> Dezembro de 1992<\/li><li><span style=\"color:#434343\" class=\"has-inline-color\"><strong>LOCALIZA\u00c7\u00c3O:<\/strong><\/span> Edif\u00edcio Juscelino Kubistchek \/ Belo Horizonte, MG<\/li><li><span style=\"color:#434343\" class=\"has-inline-color\"><strong>CLIENTE:<\/strong> <\/span>Instituto Hist\u00f3rico Geogr\u00e1fico de Minas Gerais IHG\/MG.<\/li><li><span style=\"color:#434343\" class=\"has-inline-color\"><strong>TIPO DE OBRA:<\/strong><\/span> Constru\u00e7\u00e3o Civil<\/li><li><span style=\"color:#434343\" class=\"has-inline-color\"><strong>FUN\u00c7\u00c3O DO GEOT\u00caXTIL BIDIM<\/strong>: <\/span>Camada de prote\u00e7\u00e3o no sistema de impermeabiliza\u00e7\u00e3o<\/li><li><span style=\"color:#434343\" class=\"has-inline-color\"><strong>QUANTIDADE UTILIZADA:<\/strong> <\/span>1.290 m\u00b2 de geot\u00eaxtil Bidim RT-10.<\/li><\/ul>\n\n\n\n<h4><\/h4>\n\n\n\n<p>O Instituto Hist\u00f3rico e Geogr\u00e1fico de Minas Gerais est\u00e1 sediado no Edif\u00edcio Juscelino Kubitschek, \u00e0 Guajajaras, 80 no centro de Belo Horizonte\/MG (Figura 1). A obra est\u00e1 localizada na laje de cobertura do segundo pavimento do Edif\u00edcio JK sob a qual est\u00e1 localizado o Instituto Hist\u00f3rico Geogr\u00e1fico de Minas Gerais IHG\/MG.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" width=\"1024\" height=\"718\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem7-2-1024x718.png\" alt=\"\" class=\"wp-image-2330\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem7-2-1024x718.png 1024w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem7-2-300x210.png 300w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem7-2-768x538.png 768w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem7-2.png 1303w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h4><span style=\"color:#434343\" class=\"has-inline-color\">FINALIDADE DA OBRA<\/span><\/h4>\n\n\n\n<p>Ocupando uma \u00e1rea de aproximadamente 1.200 m\u00b2 de parte do segundo andar do Edif\u00edcio JK o Instituto Hist\u00f3rico Geogr\u00e1fico de Minas Gerais enfrentou diversos problemas provenientes da a\u00e7\u00e3o das \u00e1guas (umidade) em sua estrutura ao longo do tempo.<\/p>\n\n\n\n<p>Dentre os problemas enfrenta pelo IHG\/MG citamos:<\/p>\n\n\n\n<ul><li>Goteiras e manchas;<\/li><li>Mofo e apodrecimento;<\/li><li>Ferrugem;<\/li><li>Efloresc\u00eancia;<\/li><li>Criptofloresc\u00eancia;<\/li><li>Deteriora\u00e7\u00e3o;<\/li><li>Interdi\u00e7\u00e3o de salas;<\/li><li>Perdas de arquivos, documentos, livros etc.; &#8211; Danos \u00e0s instala\u00e7\u00f5es el\u00e9tricas etc.<\/li><\/ul>\n\n\n\n<p>A fim de solucionar os problemas anteriormente cita foi proposta a impermeabiliza\u00e7\u00e3o da laje de cobertura do IHG\/MG. Segundo a NBR 8083, \u201cImpermeabiliza\u00e7\u00e3o \u00e9 a prote\u00e7\u00e3o das constru\u00e7\u00f5es contra a passagem de flui\u201d, e \u201cSistema de Impermeabiliza\u00e7\u00e3o \u00e9 o conjunto de materiais que uma vez aplica, conferem a impermeabilidade \u00e0s constru\u00e7\u00f5es\u201d.<\/p>\n\n\n\n<p>O bom desempenho do Sistema de Impermeabiliza\u00e7\u00e3o se origina na correta concep\u00e7\u00e3o do projeto, ou seja, uma perfeita intera\u00e7\u00e3o entre arquitetura, a estrutura e instala\u00e7\u00f5es (hidr\u00e1ulico-sanit\u00e1rias, el\u00e9tricas e outras). Partindo da\u00ed, a escolha correta materiais componentes, m\u00e9todo de impermeabiliza\u00e7\u00e3o e das diversas camadas que o constituir\u00e3o.<\/p>\n\n\n\n<p>Basicamente nosso Sistema de Impermeabiliza\u00e7\u00e3o constitui-se de:<\/p>\n\n\n\n<ul><li>Camada de regulariza\u00e7\u00e3o;<\/li><li>Aplica\u00e7\u00e3o da manta impermeabilizante;<\/li><li>Aplica\u00e7\u00e3o do geot\u00eaxtil Bidim como camada de prote\u00e7\u00e3o da manta impermeabilizante; &#8211; Prote\u00e7\u00e3o da camada de separa\u00e7\u00e3o.<\/li><\/ul>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"1024\" height=\"986\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem8-2-1024x986.png\" alt=\"\" class=\"wp-image-2331\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem8-2-1024x986.png 1024w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem8-2-300x289.png 300w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem8-2-768x740.png 768w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem8-2.png 1305w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n\n\n<h4><span style=\"color:#434343\" class=\"has-inline-color\">CAMADA DE REGULARIZA\u00c7\u00c3O<\/span><\/h4>\n\n\n\n<p>Para execu\u00e7\u00e3o da camada de regulariza\u00e7\u00e3o a primeira provid\u00eancia foi retirar a antiga camada de prote\u00e7\u00e3o e regulariza\u00e7\u00e3o da laje, que se encontrava danificada, apresentando trincas, rachaduras e soltando placas em diversos pontos da estrutura. A laje encontrava-se desnivelada e sem os devi caimentos para os pontos de capta\u00e7\u00e3o de \u00e1gua, estes estavam danifica e em alguns casos entupi.<\/p>\n\n\n\n<p>A segunda provid\u00eancia foi promover a declividade da laje oferecendo um caminho para a \u00e1gua. A camada de regulariza\u00e7\u00e3o foi executada sobre a estrutura portanto com objetivo de fornecer uma superf\u00edcie lisa, homog\u00eanea, firme e com os caimentos necess\u00e1rios, para aplica\u00e7\u00e3o da impermeabiliza\u00e7\u00e3o.<\/p>\n\n\n\n<p>A regulariza\u00e7\u00e3o foi constitu\u00edda de uma camada de argamassa de cimento e areia, tra\u00e7o volum\u00e9trico 1:3, sem aditivo impermeabilizante, de espessura m\u00ednima de 2 cm e caimento de no m\u00ednimo 1% (NB-279\/75) em dire\u00e7\u00e3o \u00e0 coleta de \u00e1guas pluviais.<\/p>\n\n\n\n<h4><span style=\"color:#434343\" class=\"has-inline-color\">IMPERMEABILIZA\u00c7\u00c3O<\/span><\/h4>\n\n\n\n<p>Estando a superf\u00edcie preparada, partimos para a aplica\u00e7\u00e3o do elemento impermeabilizante propriamente dito. Adotou-se no sistema de impermeabiliza\u00e7\u00e3o: manta, asfalto modificado com armadura estruturada em geot\u00eaxtil Bidim. A manta foi fixada ao substrato com ma\u00e7arico.<\/p>\n\n\n\n<p>Inicialmente aplicou-se sobre o substrato regularizado uma dem\u00e3o de solu\u00e7\u00e3o de imprima\u00e7\u00e3o (conforme NBR- 9952), consumo de 0,5 a 0,7 l\/m\u00b2. Aguardou-se ent\u00e3o a secagem, cerca de 24 horas. A manta foi desenrolada sobre a imprima\u00e7\u00e3o, aquecida com ma\u00e7arico e pressionada sobre ele de forma a propiciar a fus\u00e3o de sua camada inferior.<\/p>\n\n\n\n<p>Para aplica\u00e7\u00e3o com ma\u00e7arico a manta deve ter a superf\u00edcie inferior, que ser\u00e1 aderida ao substrato, acabada com filme pl\u00e1stico (polietileno). As emendas entre as mantas foram feitas sobrepondo lateral e longitudinalmente em 10 cm. Nas verticais a manta foi aderida da mesma forma que na horizontal.<\/p>\n\n\n\n<p>A impermeabiliza\u00e7\u00e3o adentrou nos ralos e foi aderida internamente nos mesmos e arremessada junto ao guarda corpo da laje sem alterar o conjunto arquitet\u00f4nico.<\/p>\n\n\n\n<p>Ap\u00f3s a execu\u00e7\u00e3o da impermeabiliza\u00e7\u00e3o e antes da camada de prote\u00e7\u00e3o mec\u00e2nica foi feito um teste de estanqueidade durante 72 horas, mantendo-se uma l\u00e2mina d\u2019\u00e1gua de cerca de 10 a 15cm sobre a impermeabiliza\u00e7\u00e3o. N\u00e3o foi verificado no sistema impermeabilizante.<\/p>\n\n\n\n<h4><span style=\"color:#434343\" class=\"has-inline-color\"> APLICA\u00c7\u00c3O DO GEOT\u00caXTIL BIDIM<\/span><\/h4>\n\n\n\n<p>A prote\u00e7\u00e3o do elemento impermeabilizante \u00e9 de fundamental import\u00e2ncia para o perfeito desempenho do sistema de impermeabiliza\u00e7\u00e3o, devido \u00e0s v\u00e1rias solicita\u00e7\u00f5es que ocorrem nas \u00e1reas impermeabilizadas.<\/p>\n\n\n\n<p>Podemos citar como exemplos, a\u00e7\u00f5es mec\u00e2nicas decorrentes das deforma\u00e7\u00f5es da estrutura (recalques de funda\u00e7\u00f5es, retra\u00e7\u00e3o do concreto etc.) e da utiliza\u00e7\u00e3o da cobertura (tr\u00e2nsito de pessoas, estacionamento, heliporto, instala\u00e7\u00e3o de equipamentos etc.) ou a\u00e7\u00f5es clim\u00e1ticas (incid\u00eancia de UV, impacto de granizo, varia\u00e7\u00e3o de temperatura etc.) que viriam a solicitar o elemento impermeabiliza\u00e7\u00e3o na forma de tra\u00e7\u00e3o, abras\u00e3o, puncionamento etc. A\u00e7\u00f5es mec\u00e2nicas induzem esfor\u00e7os que, dependendo de sua intensidade, podem vir a comprometer a estanqueidade do elemento impermeabilizante.<\/p>\n\n\n\n<p>A obra adotou como elemento de prote\u00e7\u00e3o ap\u00f3s uma an\u00e1lise de custo e benef\u00edcio, o geot\u00eaxtil Bidim. Suas caracter\u00edsticas de constitui\u00e7\u00e3o e distribui\u00e7\u00e3o multidirecional de filamentos; espessura; resist\u00eancia \u00e0 tra\u00e7\u00e3o; porosidade; compressibilidade; resist\u00eancia a perfura\u00e7\u00e3o por puncionamento e por estouro; flexibilidade; peso espec\u00edfico; isotropia e demais propriedades permitem que os geot\u00eaxtis Bidim desempenhem a fun\u00e7\u00e3o de elemento prote\u00e7\u00e3o intermedi\u00e1ria ao elemento impermeabilizante das seguintes maneiras:<\/p>\n\n\n\n<ol type=\"a\"><li>Prote\u00e7\u00e3o contra desgastes por abras\u00e3o;<\/li><\/ol>\n\n\n\n<p>Devido a sua espessura e a estrutura\u00e7\u00e3o filamentos cont\u00ednuos, o geot\u00eaxtil Bidim, colocado como<\/p>\n\n\n\n<p>\u201ccamada de prote\u00e7\u00e3o\u201d, evitou ocorr\u00eancia de esfor\u00e7os de abras\u00e3o sobre a manta e transmiss\u00e3o esfor\u00e7os tangenciais, oriundo das varia\u00e7\u00f5es dimensionais a que as prote\u00e7\u00f5es mec\u00e2nicas est\u00e3o sujeitas reduzindo o atrito ao plano de contato.<\/p>\n\n\n\n<ul><li>Prote\u00e7\u00e3o contra puncionamento<\/li><\/ul>\n\n\n\n<p>Devido sua espessura e resist\u00eancia mec\u00e2nica, o geot\u00eaxtil Bidim absorve esfor\u00e7os normais concentra, evitando assim que a manta se perfure.<\/p>\n\n\n\n<ul><li>Drenagem de l\u00edquidos e gases<\/li><\/ul>\n\n\n\n<p>O geot\u00eaxtil Bidim tem drenagem transversal, ou seja, permite a condu\u00e7\u00e3o de l\u00edquido e gases (flui) pelo seu corpo.<\/p>\n\n\n\n<h4><span style=\"color:#434343\" class=\"has-inline-color\">VANTAGENS NA UTILIZA\u00c7\u00c3O DO GEOT\u00caXTIL BIDIM<\/span><\/h4>\n\n\n\n<p>A aplica\u00e7\u00e3o do geot\u00eaxtil Bidim teve in\u00edcio com a limpeza da superf\u00edcie a ser instalado, removendo-se os elementos estranhos. Ap\u00f3s limpeza, aplicou-se sobre a superf\u00edcie cola para fixa\u00e7\u00e3o do geot\u00eaxtil Bidim.<\/p>\n\n\n\n<p>A bobina de geot\u00eaxtil Bidim foi desenrolada sobre a superf\u00edcie com cola e pressionada sobre ela de forma a propiciar uma melhor fixa\u00e7\u00e3o. As emendas do geot\u00eaxtil Bidim foram feitas sobrepondo lateral e longitudinalmente em 10cm. O geot\u00eaxtil Bidim adentrou nos ralos de foi aderido internamente nos mesmos (Figura 2).<\/p>\n\n\n\n<p>O geot\u00eaxtil Bidim foi arrematado junto ao guarda corpo da laje sem alterar o conjunto arquitet\u00f4nico do Edif\u00edcio JK (Figura 03).<\/p>\n\n\n\n<p>O geot\u00eaxtil Bidim e a manta impermeabilizante acompanharam tamb\u00e9m as interfer\u00eancias da estrutura, tais como uma passarela que n\u00e3o foi conclu\u00edda.<\/p>\n\n\n\n<p>Terminadas as etapas anteriores, partiu-se para a execu\u00e7\u00e3o da prote\u00e7\u00e3o da camada de separa\u00e7\u00e3o.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem9-1-1024x802.png\" alt=\"\" class=\"wp-image-2334\" width=\"840\" height=\"657\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem9-1-1024x802.png 1024w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem9-1-300x235.png 300w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem9-1-768x601.png 768w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem9-1.png 1107w\" sizes=\"(max-width: 840px) 100vw, 840px\" \/><figcaption>Figura 2 Arremate do sistema de impermeabiliza\u00e7\u00e3o dos ralos.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"1024\" height=\"390\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem10-1-1024x390.png\" alt=\"\" class=\"wp-image-2336\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem10-1-1024x390.png 1024w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem10-1-300x114.png 300w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem10-1-768x293.png 768w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem10-1-1536x585.png 1536w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/Imagem10-1-2048x780.png 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption>Figura 03 Arremate do sistema de impermeabiliza\u00e7\u00e3o no guarda corpo.<\/figcaption><\/figure><\/div>\n\n\n\n<h4><span style=\"color:#434343\" class=\"has-inline-color\">PROTE\u00c7\u00c3O DO GEOT\u00caXTIL BIDIM<\/span><\/h4>\n\n\n\n<p>A prote\u00e7\u00e3o do geot\u00eaxtil Bidim foi feita com contrapiso em argamassa de cimento e areia, tra\u00e7o volum\u00e9trico 1:4, espessura m\u00ednima de 3cm formando placas de l\u00e3 entre 1,5 a 2,0 m.<\/p>\n\n\n\n<p>As juntas entre as placas devem ser de 2 cm e as juntas perimetrais (no encontro das superf\u00edcies horizontais e verticais) devem ter abertura de no m\u00ednimo 3 cm.<\/p>\n\n\n\n<h4><span style=\"color:#434343\" class=\"has-inline-color\">BIBLIOGRAFIA<\/span><\/h4>\n\n\n\n<p>CELSO RAMOS Normas de Servi\u00e7os de Projeto e Especifica\u00e7\u00e3o de Impermeabiliza\u00e7\u00e3o IPT Nov\/1988.<\/p>\n\n\n\n<p>EVANDO, Silveira Santos Impermeabiliza\u00e7\u00f5es de Terra\u00e7os 1\u00ba Fasc\u00edculo Edi\u00e7\u00f5es Cotec 34\/87.<\/p>\n\n\n\n<p>LAERTE, Gui\u00e3o Maroni, MARCO ANT\u00d4NIO C. da Silva Ara\u00fajo, RENATO, Pandolpho Prote\u00e7\u00e3o de Mantas Elastom\u00e9ricas e Polim\u00e9ricas com Geot\u00eaxtil em obras de Impermeabiliza\u00e7\u00e3o 7\u00ba Simp\u00f3sio Brasileiro de Impermeabiliza\u00e7\u00e3o.<\/p>\n\n\n\n<h4><span style=\"color:#434343\" class=\"has-inline-color\">DOCUMENTA\u00c7\u00c3O FOTOGR\u00c1FICA<\/span><\/h4>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"439\" height=\"304\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-13.png\" alt=\"\" class=\"wp-image-2338\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-13.png 439w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-13-300x208.png 300w\" sizes=\"(max-width: 439px) 100vw, 439px\" \/><figcaption>Detalhe da impermeabiliza\u00e7\u00e3o ralos.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"438\" height=\"302\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-14.png\" alt=\"\" class=\"wp-image-2339\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-14.png 438w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-14-300x207.png 300w\" sizes=\"(max-width: 438px) 100vw, 438px\" \/><figcaption>Detalhe da Impermeabiliza\u00e7\u00e3o do guarda corpo.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"451\" height=\"302\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-15.png\" alt=\"\" class=\"wp-image-2340\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-15.png 451w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-15-300x201.png 300w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-15-360x240.png 360w\" sizes=\"(max-width: 451px) 100vw, 451px\" \/><figcaption>Teste de estanqueidade com l\u00e2mina d\u2019\u00e1gua.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"446\" height=\"302\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-16.png\" alt=\"\" class=\"wp-image-2341\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-16.png 446w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-16-300x203.png 300w\" sizes=\"(max-width: 446px) 100vw, 446px\" \/><figcaption>Teste de estanqueidade com l\u00e2mina d\u2019\u00e1gua.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"449\" height=\"304\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-17.png\" alt=\"\" class=\"wp-image-2342\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-17.png 449w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-17-300x203.png 300w\" sizes=\"(max-width: 449px) 100vw, 449px\" \/><figcaption>Aplica\u00e7\u00e3o da cola para assentamento do geot\u00eaxtil Bidim.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"443\" height=\"303\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-18.png\" alt=\"\" class=\"wp-image-2343\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-18.png 443w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-18-300x205.png 300w\" sizes=\"(max-width: 443px) 100vw, 443px\" \/><figcaption>Assentamento do geot\u00eaxtil Bidim.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"446\" height=\"300\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-19.png\" alt=\"\" class=\"wp-image-2344\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-19.png 446w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-19-300x202.png 300w\" sizes=\"(max-width: 446px) 100vw, 446px\" \/><figcaption>Detalhe da camada de prote\u00e7\u00e3o do geot\u00eaxtil Bidim.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"439\" height=\"302\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-20.png\" alt=\"\" class=\"wp-image-2345\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-20.png 439w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-20-300x206.png 300w\" sizes=\"(max-width: 439px) 100vw, 439px\" \/><figcaption>Manta asf\u00e1ltica sendo aquecida com o ma\u00e7arico para fixa\u00e7\u00e3o.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"443\" height=\"301\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-21.png\" alt=\"\" class=\"wp-image-2346\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-21.png 443w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-21-300x204.png 300w\" sizes=\"(max-width: 443px) 100vw, 443px\" \/><figcaption>Vista geral das mantas assentadas e respectivas emendas.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"453\" height=\"303\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-22.png\" alt=\"\" class=\"wp-image-2347\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-22.png 453w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-22-300x201.png 300w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-22-360x240.png 360w\" sizes=\"(max-width: 453px) 100vw, 453px\" \/><figcaption>Detalhe da impermeabiliza\u00e7\u00e3o ralos.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"448\" height=\"304\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-23.png\" alt=\"\" class=\"wp-image-2348\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-23.png 448w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-23-300x204.png 300w\" sizes=\"(max-width: 448px) 100vw, 448px\" \/><figcaption>Detalhe da Impermeabiliza\u00e7\u00e3o do guarda corpo.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"441\" height=\"302\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-24.png\" alt=\"\" class=\"wp-image-2349\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-24.png 441w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-24-300x205.png 300w\" sizes=\"(max-width: 441px) 100vw, 441px\" \/><figcaption>Detalhe da Impermeabiliza\u00e7\u00e3o do guarda corpo.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"439\" height=\"302\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-25.png\" alt=\"\" class=\"wp-image-2350\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-25.png 439w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-25-300x206.png 300w\" sizes=\"(max-width: 439px) 100vw, 439px\" \/><figcaption>Teste de estanqueidade com l\u00e2mina d&#8217;\u00e1gua.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"451\" height=\"302\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-26.png\" alt=\"\" class=\"wp-image-2351\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-26.png 451w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-26-300x201.png 300w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-26-360x240.png 360w\" sizes=\"(max-width: 451px) 100vw, 451px\" \/><figcaption>Testedeestanqueidadecom<br>l\u00e2mina d\u2019\u00e1gua.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"439\" height=\"302\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-27.png\" alt=\"\" class=\"wp-image-2352\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-27.png 439w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-27-300x206.png 300w\" sizes=\"(max-width: 439px) 100vw, 439px\" \/><figcaption>Aplica\u00e7\u00e3o da cola para<br>assentamento do Geot\u00eaxtilBidim.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"446\" height=\"302\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-29.png\" alt=\"\" class=\"wp-image-2354\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-29.png 446w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-29-300x203.png 300w\" sizes=\"(max-width: 446px) 100vw, 446px\" \/><figcaption>Assentamento do geot\u00eaxtil<br>Bidim.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"439\" height=\"304\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-30.png\" alt=\"\" class=\"wp-image-2355\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-30.png 439w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-30-300x208.png 300w\" sizes=\"(max-width: 439px) 100vw, 439px\" \/><figcaption>Detalhe da camada de prote\u00e7\u00e3o do geot\u00eaxtil Bidim.<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"448\" height=\"302\" src=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-31.png\" alt=\"\" class=\"wp-image-2356\" srcset=\"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-31.png 448w, https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-content\/uploads\/2021\/06\/image-31-300x202.png 300w\" sizes=\"(max-width: 448px) 100vw, 448px\" \/><figcaption>Vista geral da obra e da execu\u00e7\u00e3o da camada de prote\u00e7\u00e3o.<\/figcaption><\/figure><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Autor:&nbsp;Departamento T\u00e9cnico \u2013 Atividade Bidim Revisado JANEIRO 2011- Departamento T\u00e9cnico Mexichem Bidim Ltda.\ufeff RESUMO O Edif\u00edcio Juscelino Kubistchek, mais conhecido como JK, \u00e9 um projeto do Arquiteto Oscar Niemayer constituindo-se num marco da Constru\u00e7\u00e3o Civil em Belo Horizonte. A aplica\u00e7\u00e3o do geot\u00eaxtil Bidim \u00e9 vista como camada de prote\u00e7\u00e3o no sistema de impermeabiliza\u00e7\u00e3o do Edif\u00edcio [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[52],"tags":[71],"_links":{"self":[{"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/posts\/2324"}],"collection":[{"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/comments?post=2324"}],"version-history":[{"count":41,"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/posts\/2324\/revisions"}],"predecessor-version":[{"id":2393,"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/posts\/2324\/revisions\/2393"}],"wp:attachment":[{"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/media?parent=2324"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/categories?post=2324"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/diprotecgeo.com.br\/casos-de-obra\/wp-json\/wp\/v2\/tags?post=2324"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}